CycleStat® DC Counter

MC-1 and MC-1R Specifications

More Information

Ordering Information

Warranty

Home

About Us

 

Model: MC-1-12 / MC-1R-12 MC-1-24 / MC-1R-24
     
Nominal Voltage: 13.5 VDC 26 VDC
Operating Voltage: 9-15 VDC 16-28 VDC
     
Operating Current:    
Zero count, LED Off <1 mA approx. 13 mA
Non-zero count, LED on <10 mA approx. 24 mA
READ push-button pressed <100 mA <130 mA

Nuisance Count Delay: about 1 second

Maximum Count Rate: about 20 Counts per Minute

Operating Temperature: -10F to 140F

Operating Humidity: 30% to 95% non-condensing

Remote interface (MC-1R only): 6p4w telephone-type jack located on enclosure’s lower right side

Mounting Position: not critical

Fuse protection: internal self-reset type 0.2 Amp.

Reverse Polarity Protected

Dimensions: 3 1/32"h x 3 5/16"w (without the ears) x 1"d

 

Remote Indicator/Reset:

The combination LED display includes push-button with legend plate and a 10 ft. cable

Cable: 4 conductor black sheathed cable with a 6p4w telephone-type plug on the free end

Dimensions: 1 1/2"h x 2"w

Hole Diameter: 1/8"

 

Please note that the CycleStat® DC Counter is not rated for use in confined spaces where explosive vapors may exist. Do not install this unit in enclosed engine or tank spaces of gasoline powered vessels.

 

sales@cyclestat.com

© 2001-2009 ESC Products Corporation